The Model 500 adds a closed UV-C irradiation chamber to your water circulation system. This chamber kills microorganisms and suspended algae freely present in the water or prevents them from further cell division.
Product data at a glance
| Net volume | up to 500 liters |
|---|---|
| Disinfection at approx. 450 l/h | 90 % |
| Disinfection at approx. 250 l/h | 99 % |
| Gerätelänge | 560 mm |
| nozzle diameter and hose | 15mm (12/16 hose) |
| input | 15 watts |
| tension | 220 V |
| Proportion of UV-C radiation | 33% |
| UV-C output | 4.900 mW |
| Average burning time | 10.000 - 12.000 h |
Adjust the flow rate accordingly
The specified disinfection values vary depending on the flow rate. Take this into account when planning your water circuit.
Installation and visual inspection
Check the device length and hose size before purchasing. The special glass casing allows you to monitor the burner and the condition of the irradiation chamber.
Application and important notes
Mount the device vertically with the cable side facing down.
The flow-related disinfection values do not guarantee complete disinfection of the entire aquarium. A maximum germ reduction of approximately 98% is specified for the entire aquarium system.